D-86
Parameter Reference
PNO
Parameter Descriptions
0498
Ramping Active
Set TRUE when ramping.
0499
Ramp Spd Setpoint Input
Input speed setpoint to the ramp
0500
Ramp Speed Output
Output speed
0501
Jog Setpoint
The setpoint is the target reference that the Drive will ramp to
0502
Jog Acceleration Time
The time that the Drive will take to ramp the jog setpoint from 0.00% to 100.00%.
0503
Jog Deceleration Time
The time that the Drive will take to ramp the jog setpoint from 100.00% to 0.00%.
0504
Stop Ramp Time
Rate at which the demand is ramped to zero after the ramp has been quenched
0505
Zero Speed Threshold
Hold for zero speed detection used by stop sequences
0506
Zero Speed Stop Delay
Sets the time at which the Drive holds zero speed before quenching after a normal stop or a jog stop. This may be particularly useful
if a mechanical brake requires time to operate at zero speed, or for jogging a machine to position
0507
Quickstop Time Limit
Maximum time that the Drive will try to Quickstop, before quenching
0508
Quickstop RampTime
Rate at which the Speed Demand is ramped to zero when Quickstop is active
0509
Final Stop Rate
Rate at which any internally generated setpoint trims are removed. For example, the trim due to the slip compensation in Volts/Hz
control mode.
AC30V series Variable Speed Drive