IO Configure
Setup::Inputs and Outputs
Parameters::Inputs And Outputs::IO Configure
These parameters are used to configure the input signal processing.
PNO
Parameter Descriptions
0001
Anin 01 Type
Analog input 1 is associated with terminal X11.1
The signal processing electronics for analog input 1 supports four input ranges:
0.
1.
2.
3.
0957
Anin 01 Offset
The offset is expressed as a percentage of the hardware range selected by 0001 Anin 01 Type. For example, with the 4..20mA
range an offset of 10% is equivalent to 1.6mA on the input.
The offset is added to the measured value.
0958
Anin 01 Scale
The scale is a simple multiplication factor. The input voltage or current is converted to a percentage value. 0957 Anin 01 Offset is
added and the result is multiplied by 0958 Anin 01 Scale. The result is presented in parameter 0039 Anin 01 Value.
0002
Anin 02 Type
Analog input 2 is associated with terminal X11.2
The signal processing electronics for analog input 2 supports two input ranges:
0.
1.
0959
Anin 02 Offset
The offset is expressed as a percentage of the hardware range selected by 0002 Anin 02 Type. For example, with the -10..10V
range an offset of 10% is equivalent to 1v on the input.
The offset is added to the measured value.
0960
Anin 02 Scale
The scale is a simple multiplication factor. The input voltage is converted to a percentage value. 0959 Anin 02 Offset is added and
the result is multiplied by 0960 Anin 02 Scale. The result is presented in parameter 0041 Anin 02 Value.
AC30V series Variable Speed Drive
-10..10V
0..10V
0..20MA
4..20MA
-10..10V
0..10V
D-49
Parameter Reference