Analog Input; Analog Output - Parker AC30V Série Manuel Technique

Masquer les pouces Voir aussi pour AC30V Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

D-51
Parameter Reference
Functional Description
The values associated with each terminal are shown in the IO Values parameter (D-53).

Analog input

The input signal is converted to a percentage of the selected hardware range. For the -10V...10V range the input is represented as -100 to 100%,
for all other ranges the input is represented as 0 to 100%. The Offset value is then added to this input and the result of this is multiplied by the
scale factor. The result is presented in the Value parameter.
Offset %
Scale
+
x
Input
0...100%
Value
or
-100...100%

Analog output

The output demand value is multiplied by Scale before being added to the Offset. If ABS is TRUE the absolute value of this result is used. The
output demand value is expressed as a percentage of the selected range.
Scale
Offset
ABS
x
+
Demand
0...100%
|
|
Result
Value %
or
-100...100%
AC30V series Variable Speed Drive

Publicité

Table des Matières
loading

Table des Matières