Apron
Other oiling points
Lubrication points can be found on the drive shaft, on the lead screw and feed rod, on the slides,
on the handwheels and on the tailstock. Lubricate these points regularly with a grease gun. See
Maintenance.
17.2.8
Filling with coolant
High temperatures occur at the cutting edge of the tool due to the frictional heat. The tool should
therefore be cooled during turning. Cooling with a suitable coolant will improve the work result
and prolong the tool life. Therefore, fill with coolant. Use a water-soluble, environmentally
compatible emulsion as coolant, which is available from specialty retailers (e.g. KSM5L).
The coolant tank is located in the right foot of the machine, below the tailstock.
Loose the 4 Allen screws and remove the cover.
Check the coolant at regular intervals. Make sure that:
there is sufficient coolant available,
the chip mirror in the first chamber is not too high and
the coolant is not rancid or contaminated.
Apply coolant
1.
Make sure that the coolant tank is properly maintained and filled.
2. Position the coolant nozzle as required for your operation.
3. Use the switch on the control panel to turn the coolant pump on or off.
4. Use the flow valve to regulate the flow of coolant.
17.2.9
Function test
Check all spindles for ease of movement!
17.3
Electrical connection
Dangerous electrical voltage! Connection of the machine as well as electrical
inspections, maintenance and repair may only be carried out by qualified personnel or
under the supervision and supervision of a qualified electrician!
1.
Check that the neutral connection and protective earthing are functioning properly
2. Check that the supply voltage and current frequency correspond to the specifications of
the machine
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
Check the oil level regularly using the oil sight glass (3) on the
front.
First oil change after 100 operating hours, then change the oil
once a year or after 1000 operating hours.
See Maintenance
NOTICE
Coolants are toxic and must not be released into the environment! Follow
the manufacturer's instructions and contact your local authority for
information on proper disposal if necessary. Operating the coolant pump
without coolant in the tank can permanently damage the pump.
WARNING