John Bean b 9200 Manuel D'utilisation page 90

Table des Matières

Publicité

90
Trouble shooting
4. Wrong reference mark (single or double) was used
when readjusting the tyre.
5. Wheel moved on clamping means during a measuring
run (sudden start or braking).
6. Wheel dimensions were not set correctly.
• Repeat optimisation.
E15
Recalibration correction is out of range.
During recalibration values above or below the calibration
value envisaged were found. This message is only a
warning. Press key "C" to transfer the correction values
to the permanent memory.
• Use the clamping means supplied with the machine
or perform basic calibration (Service).
E16
During the first user calibration run the calibration weight
was attached by mistake.
• Unscrew the calibration weight and spin the wheel.
E83
During a measuring run the values measured are
rendered useless due to outside interference pulses
(e.g.: bumps). The run is interrupted.
• Repeat the measuring run.
E88
The main shaft speed exceeds the safety limit.
E89
A key is jammed.
• Find and release jammed key, if necessary call
service team.
E92
The gauge arm for measuring the offset and diameter
is faulty.
• Call service team.
• As long as the gauge arm is defective, set the offset
and rim dimensions using the menu key and turning
the wheel (Chapter 2.3.3).
Operator's Manual
b 9200

Publicité

Table des Matières
loading

Table des Matières