90
Trouble shooting
4. Wrong reference mark (single or double) was used
when readjusting the tyre.
5. Wheel moved on clamping means during a measuring
run (sudden start or braking).
6. Wheel dimensions were not set correctly.
• Repeat optimisation.
E15
Recalibration correction is out of range.
During recalibration values above or below the calibration
value envisaged were found. This message is only a
warning. Press key "C" to transfer the correction values
to the permanent memory.
• Use the clamping means supplied with the machine
or perform basic calibration (Service).
E16
During the first user calibration run the calibration weight
was attached by mistake.
• Unscrew the calibration weight and spin the wheel.
E83
During a measuring run the values measured are
rendered useless due to outside interference pulses
(e.g.: bumps). The run is interrupted.
• Repeat the measuring run.
E88
The main shaft speed exceeds the safety limit.
E89
A key is jammed.
• Find and release jammed key, if necessary call
service team.
E92
The gauge arm for measuring the offset and diameter
is faulty.
• Call service team.
• As long as the gauge arm is defective, set the offset
and rim dimensions using the menu key and turning
the wheel (Chapter 2.3.3).
Operator's Manual
b 9200