Installation Instructions
This appendix describes the installation requirements,
installation procedures and checks.
i. Installation requirements
Space requirements.
The drawing show the minimum safety requirements.
i-1
For measurements regarding overall machine surface
space
Floor requirements.
In the support area of the machine, the floor should
-
horizontal;
+/-1° of tollerance.
-
even; within 2 mm
-
able to bear the weight of the balancer as stated
in Chapter 2 of the Operator's Manual.
The floor on which the balancer will be installed
should not relay vibrations from other devices or from
outside the building. External vibrations may affect
the accuracy of the unit.
Note:
The balancer must be positioned directly
on the floor. Do not use spacers to fill gaps.
If the above conditions are satisfied, the balancer does
not need fixing to the floor.
Power supply requirements.
Refer to Chapter 2 of the Operator's Manual for mains
power requirements.
WARNING: ENSURE THAT AN APPROVED WALL
MAINS OUTLET IS AVAILABLE.
WARNING: NEVER GUIDE POWER SUPPLY
CABLES OVER THE FLOOR, UNLESS
PROTECTED BY AN APPROVED COVER.