78
5.6-10
5.6-11
5.6-12
Operation
Code C8
Figure 5.6-10 Selecting the threshold value for
suppressing minor imbalances in grams or oz. The unit
of measure depends on the C3 code setting.
Unit of measure: grams:
see table at end of manual.
Unit of measure: oz:
see table at end of manual.
The operating mode selected can be obtained from the
permanent memory.
Code C10
Figure 5.6-11 Saving an operating mode in the
permanent memory.
0*
=
Don't save
1
=
Save the data in the permanent memory.
The machine sounds a three tone beep to confirm
that the data has been saved permanently.
If you have to save the operating mode permanently,
first change the state, e.g. activate it, disable it and
then save it in the permanent memory using the C10
code (this does not apply to C4).
Code C12
Figure 5.6-12 Measuring run counter.
Example: 222.123 measuring runs performed
Press the Fine key and spin the wheel to display the
following counters:
1 = Total nr. of measuring runs performed
2 = Total nr. of measuring runs with a positive balancing
result (OK)
3 = Total nr. of optimisations and minimisations
4 = Total nr. of measuring runs in Service mode
5 = Total nr. of measuring runs since the last calibration
Every measuring run that is performed and concluded
is memorised. The counter can count up to 999,999
measuring runs. When this number is reached the
counter starts again from 0. This information is
interesting in terms of statistics, e.g. to demonstrate
how long faulty parts have lasted or to calculate how
much the machine is used per month or per year.
The measuring cycles performed while the machine is
running are saved in the permanent memory and totalled
every time the machine is turned OFF. Counter totals
cannot be deleted.
Operator's Manual
b 9200

Publicité

Table des Matières
loading

Table des Matières