John Bean b 9200 Manuel D'utilisation page 76

Table des Matières

Publicité

76
5.6-7
5.6-8
5.6-9
Operation
Code C4
Figure 5.6-7 Compensation of clamping device residual
imbalance (if any).
High precision measuring (This operating mode cannot
be stored in the permanent memory).
Once compensation has been performed, if the clamping
device is changed, this value must be deleted or
recalculated using the new device.
To delete clamping device compensation , set the
operating state to 0.
Compensation should be deleted when the machine is
calibrated or recalibrated, if imbalance optimisation
(silencing) is performed or if the machine is turned OFF
.
0
=
Perform compensation
1
=
Compensation performed
0
=
Disable compensation after the measuring run
Code C6
Figure 5.6-8 Entering the number of wheel spins per
measuring run. Between 10 and 30 spins are possible,
preset by the manufacturer at 10 spins per run.
Example > change to 15 spins per run.
WARNING: REDUCING THE NUMBER OF SPINS PER
RUN MEANS THAT THE MEASUREMENT WILL BE
LESS PRECISE.
The operating mode selected can be obtained from the
permanent memory.
Code C7
Figure 5.6-9 Adjusting beep volume, from 0 to 100 (quiet
- loud) preset by the manufacturer at 50*.
Example: Change volume to 60.
To confirm the volume change, exit the function by
pressing the C key.
The operating mode selected can be obtained from the
permanent memory.
Operator's Manual
b 9200

Publicité

Table des Matières
loading

Table des Matières