6. Loop the green jumper wire removed from the ground screw back onto its end that is
fastened to the center post on the terminal block.
7. Use 5/16" nut driver to connect the neutral (white) wire to the center terminal block post
with one of the 10-32 hex nuts.
8. Using 10-32 hex nuts, connect the red and black wires from the power cord to the outer
posts of the terminal block with the corresponding red and black wires from the range.
9. Tighten the hex nuts completely, and then verify the connection.
10. Position the lower part of the strain relief under the flexible metal conduit and tighten
the strain relief screws.
NOTE: Before tightening, make sure the strain relief is positioned over the flexible
metal conduit and NOT the wires.
11. Replace the electrical access panel.
12. Tuck excess conduit into the recessed area of the back panel.
STEP 4 - INSTALL RANGE
IMPORTANT: If the range is moved to adjust the leveling legs, make sure when you move
the range back into its final location that the anti-tip bracket is engaged by repeating steps
1 through 9.
1. Slide range into final location, making sure rear leveling leg slides into anti-tip bracket.
Leave a l" (2.e cm) gap between the back of the range and the back wall.
2. Place the outside of your foot against the bottom front to keep the range from moving,
and then grasp the back of the range, as shown.
3. Slowly attempt to tilt the range forward.
If you encounter immediate resistance, the range foot is engaged in the anti-tip bracket.
Go to Step 8.
4. If the rear of the range lifts more than 1/2" (l.3 cm) off the floor without resistance, stop
tilting the range and lower it gently back to the floor. The range foot is not engaged in the
anti-tip bracket.
60