A UL Listed Strain Relief
5. Using a 5/16" nut driver and one of the -0-32 hex nuts, connect the neutral (white) wire
from the power cord to the center terminal block post along with the green jumper wire
from the range.
6. Using 10-32 hex nuts, connect the red and black wires from the power cord to the outer
posts of the terminal block with the corresponding red and black wires from the range.
7. Tighten the hex nuts completely, and then verify the connection.
NOTE: For power supply cord replacement, use only a power cord rated at 250 volts
minimum, 50-amps that is marked for use with nominal 1 3/8" (3.5 cm) diameter
connection opening, with ring terminals and marked for use with ranges.
8. Position the lower part of the strain relief under the power cord and tighten the strain
relief screws.
NOTE: Before tightening, make sure the strain relief is positioned over the cord and
NOT the wires.
9. Replace the electrical access panel.
10. Plug range into grounded outlet.
11. Tuck excess power cord into the recessed area of the back panel.
4-WIRE CONNECTION: POWER SUPPLY CORD
IMPORTANT: Use this method for new branch-circuit installations (1996 NEC), mobile
homes, recreational vehicles, or in an area where local codes prohibit grounding through
the neutral.
1. Disconnect power.
2. Remove the access panel located on the bottom right-hand side of the back panel to
expose the electrical terminal block.