For direct wire installations, install a suitable conduit box (not furnished). An
appropriately sized, UL conduit connector must be used to correctly attach the conduit to
the junction box.
IMPORTANT: Local Codes may vary; installation electrical connections and grounding
must comply with all applicable local codes.
ELECTRICAL REQUIREMENTS - U.S.A. ONLY
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate and in conformance with
the National Electrical Code, ANSI/ NFPA No. 70-latest edition and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection
Association One Batterymarch
Park
Quincy, MA 02269
WARNING
Electrical Shock Hazard
The electrical power to the oven branch circuit must be shut off while line connections are
being made.
Do not use an extension cord with this appliance.
Electrical ground is required on this appliance. The free end of the green wire (the ground
wire) must be connected to a suitable ground. This wire must remain grounded to the
oven.
If cold water pipe is interrupted by plastic, non metallic gaskets, union connections or
other insulating materials, DO NOT use for grounding.
DO NOT ground to a gas pipe.
DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in the NEUTRAL or
GROUNDING circuit could result in an electrical shock.
Check with a qualified electrician if you are in doubt as to whether the appliance is properly
grounded.
Failure to do so could result in death, fire or electric shock.
The range is not equipped with a power cord. The range can be fitted with a 3 or 4-wire
NEMA 14-50 or 10-50 type SRDT or ST (as required) power cord rated at 250 volt AC
minimum, 50 amp, with 3 open-end spade lug connectors with upturned ends or closed
loop connectors and marked for use with ranges.
A UL listed strain relief must be attached to the range to hold the power cord.