Télécharger Imprimer la page

Kenmore 982.9684 Serie Guide D'utilisation Et D'entretien page 54

Publicité

3. Install a UL listed strain relief to the power cord opening in the support bracket, and fully
tighten the strain relief nut.
4. Feed the power supply cord through the strain relief. Allow enough slack to easily attach
the wiring to the terminal block.
A Ground Screw
B Terminal Block
C Jumper Wire
5. Remove the green jumper wire from under the ground screw and replace with the green
wire from the power cord and tighten ground screw.
6. Loop the green jumper wire removed from the ground screw back onto its end that is
fastened to the center post on the terminal block.
7. Use 5/16" nut driver to connect the neutral (white) wire to the center terminal block post
with one of the 10-32 hex nuts.
8. Using 10-32 hex nuts, connect the red and black wires from the power cord to the outer
posts of the terminal block with the corresponding red and black wires from the range.
9. Tighten the hex nuts completely, and then verify the connection.
A Access Panel to Electrical Supply
Connection
B Power Cord Opening
C Recessed Area
D Power Cord Wires
E UL Listed Strain Relief
54

Publicité

loading

Ce manuel est également adapté pour:

982.9683 serie