Do not use an aluminum wire receptacle with copper-wired power cord and plug (or
vice versa). The proper wiring and receptacle is a copper-wired power cord with a
copper-wired receptacle.
The electrical outlet should be located so that the power cord is accessible when the
range is in the installed position.
ELECTRICAL REQUIREMENTS - CANADA ONLY
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Plug into a grounded outlet.
Do not use an extension cord.
Failure to do so can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified
electrical installer determine that the ground path is adequate and wire gauge are in
accordance with local codes.
Be sure that the electrical connection and wire size are adequate and in conformance with
CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards
Association 178 Rexdale Blvd.
Toronto, ON M9W 1R3
CANADA
Check with a qualified electrical installer if you are not sure the range is properly
grounded.
This range is equipped with a CSA International Certified Power Cord intended to be
plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within
reach of range's final location.