A Junction Box
B Black Wires
C Neutral (White) Wire
2. Connect the 2 black wires B together using a UL listed wire connector.
3. Connect the neutral (white) wire C and the ground (green or bare) wired (of the range
cable) using a UL listed wire connector.
4. Connect the 2 red wires G together using a UL listed wire connector.
5. Install junction box cover.
Connect to the Range
IMPORTANT: Use this method only if local codes permit connecting chassis ground
conductor to neutral wire of power supply cord.
1. Feed the electric cable wires through the flexible metal conduit.
NOTE: Allow enough slack to easily attach the wires to the terminal block.
2. Remove the access panel located on the bottom right-hand side of the back panel to
uncover the electrical terminal block.
3. Install a UL listed strain relief (not provided) to the conduit opening in the bracket, and
then completely tighten the strain relief nut.
4. Thread the end of the conduit through the strain relief.
NOTE: Allow enough slack to connect the wires to the terminal block.
A Jumper Wire
D Ground (Green or Bare)
Wire
E Cable from Range
F
UL
Listed
Connector
A Electrical Access Panel
B Conduit Opening
C Recessed Area
B UL Listed Strain Relief
57
G Red Wires
H UL Listed Wire Connectors
I House Electrical Supply
Conduit
C Conduit