STEP 3 - MAKE ELECTRICAL CONNECTION
After reading the requirements for each Electrical Connection method, follow the
instructions specific to your situation.
POWER CORD - U.S.A. ONLY
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 50 amp UL listed or CSA certified power supply cord for 240V, 45amp for 208V.
Plug into a grounded outlet.
Do not use an extension cord.
Failure to do so can result in death, re, or electrical shock.
3-WIRE CONNECTION: POWER SUPPLY CORD
IMPORTANT: Use this method only if local codes permit connecting chassis ground
conductor to neutral wire of power supply cord.
1. Disconnect power.
2. Remove the access panel located on the bottom right-hand side of the back panel to
uncover the electrical terminal block.
3. Install a UL listed strain relief (not provided) to the power cord opening in the bracket,
and then completely tighten the strain relief nut.
4. Thread the end of the power cord through the strain relief.
NOTE: Allow enough slack to connect the wires to the terminal block.
A
Access
Panel
Connection
B Power Cord Opening
C Recessed Area
52
to
Electrical