FAULT
Alarm
Fault
W07
ROI pre-fi lter fi nishing.
Osmosis membrane about to
W08
expire.
W10
Servicing required
One point of the core probe
W11
is faulty
W12
Servicing Deadline Warning
Cleaning was interrupted by
WARNING!
means of the START/STOP
cleaning
interrupted
button
3413811_ut_GB_rev.2
Remedy
Replace the ROI pre-fi lter as
soon as possible
Replace the ROI osmosis mem-
brane as soon as possible.
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Restart cleaning or carry out
an emergency rinse.
Notes
The oven's functions are ena-
bled so cooking cycles can be
carried out.
The oven's functions are ena-
bled so cooking cycles can be
carried out.
The oven's functions are ena-
bled so cooking cycles can be
carried out.
The oven's functions are ena-
bled so cooking cycles can be
carried out.
The oven's functions are ena-
bled so cooking cycles can be
carried out.
It is not possible to carry out
cooking cycles until a com-
plete washing cycle or emer-
gency rinse cycle has been car-
ried out
ENGLISH
51