Equipotential Connection - Apach AP Serie Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
CABLE SUBSTITUTION
This must be carried out by a qualified authorized technician. The earth wire must always
be yellow green.
WARNING: the yellow/green voltage wires in the earth cable must be 3cm longer than the
others.
Proceed as follows to connect the power supply wire to the terminal board:
(A1)
Loosen the tops of the cable gland and open the side part of the appliance by
loosening the screws.
(A3)
Loosen the terminal screws and feed the cable conductors through. Take out the
old cable from the cable gland.
(A2)
Feed the new cable through the cable gland.
Connect the new cable's conductors to the terminal following the connection
diagram on the label at the lower part of the back of the appliance.
Only connect what is indicated inserting the copper bridge and the electricity cable
together under the screws, in the tightening direction, so the cable and the bridge
are tightly fixed by tightening the screw.
The type of cable to be used (HO7RN-F) is indicated on the label for each
connection and the voltage sections in mm².
(A4)
Close the side part of the appliance by tightening the screws and fit the cable by
tightening the cable gland top.
Check that all the connections are tight before connecting the oven to the mains.
WARNING: Erroneous connection could lead to overheating of the terminal board which
could lead to blowout and electric shock.
Check there is no static discharge between live and earth.
Check the limit switch continuity between the external casing and the earth wire of the mains.
It is advised to use a multi tester to carry out these operations
The appliance must be connected to the mains using a H07RN-F cable.

EQUIPOTENTIAL CONNECTION

This connection shall be carried between the different appliances
with the terminal marked by the symbol: (see image).
This terminal enables the connection of Yellow/Green cable with a
section between 2.5 and 10mm².
The appliance shall be included in an equipotential system whose
efficiency shall be duly verified according to the provisions of the
laws in force.
E n g l i s h