IMPORTANT

ATTENTION: to guarantee the cleaning system's perfect operation, make sure that the
temperature of the cooking chamber is between 90 °C and 140 °C before starting a cleaning
program (CLN_01, CLN_02, CLN_03). Higher temperatures are not recommended.
The equipment is intended to clean professional ovens. Any use other than that indicated must
be avoided, as this will be considered improper use and, therefore, dangerous.
Before starting a cleaning cycle, make sure that the water drain on the bottom of the cooking
chamber is clear, to prevent flooding the chamber.
Never open the cooking chamber when a cleaning cycle is in progress. Chemical substances
and hot fumes may escape causing burns and corrosion.
At the end of every cleaning cycle, make sure that no detergent residue is left in the cooking
chamber. Remove any residue from the cooking chamber and rinse manually.
We recommend using the detergent approved by the manufacturer.
The use of a non-approved detergent may damage the cleaning system and may affect the
integrity of the cooking chamber, rendering the warranty null and void.
-

WARNINGS AND ALARMS

All alarms are indicated by a buzzer. The buzzer can be silenced by pressing a key.
Er1 CHAMBER PROBE ALARM:
This is triggered if the chamber probe fails. Everything is deactivated except for the light.
The cycle in progress is interrupted.
Er2 CORE PROBE ALARM
This is triggered if the core probe in the food being cooked fails (where used). Everything
is deactivated except for the light. The cycle in progress is interrupted.
ALL MOTOR ALARM
This is triggered if the motor overheats. Everything is deactivated except for the light. The
cycle in progress is interrupted.
Once the alarm is silenced, press the ON/OFF button for one second to reset the alarm
(the control panel is set to OFF).
H-t CONTROL BOARD TEMPERATURE ALARM
This is triggered if the control board overheats. The cycle in progress is interrupted.
Once the alarm is silenced, press the ON/OFF button for one second to reset the alarm
(the control panel is set to OFF).