20.
TROUBLESHOOTING
DIRECT HEAT GAS BOILING PAN
THE PILOT BURNER DOES NOT LIGHT.
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Igniter defective or not properly connected.
- Igniter or igniter wire defective.
PILOT BURNER GOES OUT DURING USE
Possible causes:
- Insufficient gas supply pressure.
- Defective gas tap or valve.
- Defective thermocouple or insufficient heating.
- Thermocouple incorrectly connected to gas tap or
valve.
-
Knob of gas tap or valve not pressed a.
THE MAIN BURNER DOES NOT LIGHT (EVEN
THOUGH PILOT IS LIT)
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Defective burner (gas outlet holes clogged).
- Defective energy regulator.
HEATING CANNOT BE ADJUSTED
Possible causes:
- Defective energy regulator.
INDIRECT HEAT GAS BOILING PAN
THE PILOT BURNER DOES NOT LIGHT.
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Igniter defective or not properly connected.
- Igniter or igniter wire defective.
PILOT BURNER GOES OUT DURING USE
Possible causes:
- Insufficient gas supply pressure.
- Defective gas tap or valve.
- Defective thermocouple or insufficient heating.
- Thermocouple incorrectly connected to gas tap or
valve.
-
Knob of gas tap or valve not pressed a.
THE MAIN BURNER DOES NOT LIGHT (EVEN
THOUGH PILOT IS LIT)
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Defective burner (gas outlet holes clogged).
- Defective energy regulator.
- Defective pressure switch.
HEATING CANNOT BE ADJUSTED
Possible causes:
- Defective energy regulator.
DIRECT HEAT ELECTRIC BOILING PAN
THE APPLIANCE DOES NOT HEAT.
Possible causes:
- Defective energy regulator.
- Heating elements defective.
- Safety thermostat tripped.
HEATING CANNOT BE ADJUSTED
Possible causes:
- Temperature thermostat defective.
INDIRECT HEAT ELECTRIC BOILING PAN
THE APPLIANCE DOES NOT HEAT.
Possible causes:
- Defective energy regulator.
- Heating elements defective.
37