Direct Heat Gas Boiling Pan - Modular 90/80 PGD100 Traduction Des Instructions D'origine

Appareil pour la cuisson d'aliments destiné à un usage industriel
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
working life of the appliance.
Installation and appliance maintenance must be
carried out by qualified technicians authorized by
the manufacturer, in compliance with current
safety standards and the instructions in this
manual.
Appliance maintenance and conversion to a
different type of gas must be carried out by
qualified technicians authorized by the
manufacturer, in compliance with current safety
standards and the instructions in this manual.
With indirect heat boiling pans and boiling pans
with autoclave lid, do not open drain taps or other
emptying devices until the pressure has reduced to
approximately atmospheric pressure.
IMPORTAT! IN ORDER TO REDUCE
WEAR AND PREVENT THE BREAKAGE OF
OUTLET , PERIODICALLY LUBRICATE IT
(ONCE A WEEK) USING COOKING FATS.
11.

DIRECT HEAT GAS BOILING PAN

The appliance is designed for cooking and
preparing food in water.
Do not light the pilot burner or leave it on when
there is no water in the well.
Do not activate the heating system when there is
no water in the well.
While the appliance is on, the water level must be
maintained level with or above the minimum level
indicated on the wall of the tank.
Use very fine grained salt, adding it to the well
when the water is boiling. Do not use
coarsegrained rock salt in the well.
At the end of each day, clean the well thoroughly in
order to prevent the formation of corrosive
deposits.
FILLING AND EMPTYING OF THE TANK
FILLING
The control knob has the following positions:
OFF
(BLUE) COLD WATER FI LLING
ELECTRICAL POWER ON
(RED) HOT WATER FI LLING
Open the lid.
Turn the handle of the front discharge tap
clockwise. The tap is only completely closed when
the handle is in the vertical position.
Turn the control knob to select hot or cold water for
filling.
Water fills from dispenser place on the countertop.
Fill the well until the water is level with the
maximum level indicated on the wall of the well. Do
not use the appliance with the water level above
the maximum indicated level.
To halt filling, turn the knob to position " 0 " or " 1 "
.
EMPTYING
Lift and turn the handle of the front discharge tap
anti-clockwise.When the tap is open the handle
remains in the horizontal position.
BURNER IGNITION AND EXTINCTION
The gas valve control knob has the following
positions:
OFF
PILOT IGNITION
MAX. FLAME
PILOT IGNITION
Make sure the control knob is turned to "1".
Press and turn knob to "pilot on".
29

Publicité

Table des Matières
loading