Télécharger Imprimer la page

Dräger Polytron 5000 Serie Notice D'utilisation page 32

Masquer les pouces Voir aussi pour Polytron 5000 Serie:

Publicité

en
|
Accessories and spare parts
Installation
The instrument may only be opened in the temperature range
from 5 °C to 40 °C. The temperature and the maximum
humidity must be within the following limits:
5 °C
31 °C
34 °C
max.
max.
max.
80% RH
80% RH
70% RH
Possible installation locations:
– at an altitude of max. 2000 m above sea level
– indoors
– outdoors
– in wet environments
15.8 Tightening torques
Instrument threads
Housing cover
Sensor
Blind plugs on the trans-
mitter housing
Ports (for conduits or
cable glands) on the
transmitter housing
Blind plugs on the dock-
ing station
Cable glands on the
docking station
Field wiring terminals
Power supply, signals
and relays
Grounding screw
16
Accessories and spare parts
This section provides an overview of the components that are
covered by the TÜV 19 ATEX 8435 X and
TÜV 22 UKEX 7076 X type examinations. Further parts are
listed in the spare parts list or can be requested from
DrägerService.
®
16.1 Polytron
5xx0
Description
IRDA to PC interface
Magnetic wand with key
chain
Dräger PolySoft configuration
software
Ex d blind plug, stainless
steel (2 pcs)
32
37 °C
40 °C
max.
max.
600% RH
50% RH
7 ±2 Nm (62 ±17.7 LB IN.)
min. 30 Nm (min. 266 LB. IN.)
min. 30 Nm (min. 266 LB. IN.)
min. 50 Nm (min. 443 LB. IN.)
7 Nm (62 LB. IN.)
8 Nm (70 LB. IN.)
0.5 Nm to 0.8 Nm (4.4 LB.IN. to
7.0 LB. IN.)
1.2 Nm (10.6 LB. IN.)
Part number
4544197
4544101
8328600 / 8328639
4544897
Description
Ex d blind plug, galvanic steel
(3 pcs)
Relay board
16.1.1 Docking station
Description
Docking station, voltage only
version
Docking station voltage, relay
(contains 2 cable glands)
Docking station cable gland
Docking station blind plugs
®
16.2 Polytron
5100 EC
Description
Printed circuit board unit
Polytron 5100 EC
PE calibration adapter,
Europe
Bayonet ring
Duct adapter for remote EC
sensing head
Rod attachment for remote
EC sensing head
®
16.3 Polytron
5200 CAT
Description
Printed circuit board unit
Polytron 5200 CAT
PE calibration adapter,
Europe
DQ remote calibration
adapter
LC remote calibration
1)
adapter
21.50X14.50 membranes
spare part set, 2 pcs.
Dust filters for
DrägerSensor DQ, 10 pcs.
DQ process adapter
1)
LC process adapter
Splash guard
1) not covered by performance approval.
Instructions for use
Part number
8344041
4544297
Part number
8344027
8344028
6812868
8344042
Part number
4544086
6806978
4544366
8317617
4544213
Part number
4544084
6806978
6812480
6812482
8326840
6810537
6812470
6812465
6812510
|
Dräger Polytron 5000 Series

Publicité

loading