Menu
Default setting
Full scale setting
100 %LEL
PIR LOCK
off
PIR password
_ _ _ 2 (3x blank
spaces, then 2)
15.6.4.5 Polytron 5720 IR
Menu
Default setting
Test gas
CO
2
Test gas units
Vol%
Test gas concen-
2.5 Vol%
trations
A1 alarm
1 Vol%
A2 alarm
2 Vol%
LEL type
-
Measured gas
CO
2
Units of measured
Vol%
gas
Full scale setting
10 Vol%
PIR LOCK
off
PIR password
_ _ _ 2 (3x blank
spaces, then 2)
Instructions for use
|
Dräger Polytron 5000 Series
15.7 Environmental parameters
Range
General information
Unit is Vol%, FSD
options: {1, 2, 5, 10,
Sensor specifications and influences can be found in the
20, 30, 50,100}
instructions for use provided for the respective sensor.
Unit is %LEL. FSD
The values for accessories and spare parts may deviate from
options: {20, 50,
the values given here. The exact values can be found in the
100}
corresponding manual.
Unit is ppm, FSD
options: {500,
Temperatures
1000, 2000, 5000,
9999}
Polytron 5000
on/off
During operation:
Pressure
Humidity
Temperatures
Range
If the unit is Vol%
and FSD < 10,
range: {0.01 to
FSD}
Or if the unit is
Vol% and
10 ≤ FSD < 100,
range: {0.1 to FSD}
Or if the unit is
Vol% or ppm and
During storage:
FSD ≥ 100, range:
{1 to FSD}
Pressure
0.01 to 100 Vol%
Humidity
Temperature
Recommended storage
period
Vol%
Values for relay option and installations with UL
approval
Unit is Vol%, actual
During operation:
FSD options: {1, 2,
5, 10, 20, 30,
Temperatures
50,100}
Unit is ppm, actual
FSD options: {500,
1) See instructions for use provided for the EC sensor for the constraints
1000, 2000, 5000,
9999}
2) Value from the Ex approval. For values with this footnote, the values
on/off
Danger of fire or electric shock for instruments with relay
► The specified temperatures must not be exceeded to
700 hPa to 1300 hPa
(20.7 in. Hg to 38.4 in. Hg)
0 to 100% RH, non-condensing
-40 °C to +65 °C (-40 °F to
1)
Polytron 5100 EC
+149 °F)
-40 °C to +70 °C
+158 °F)
Polytron 5200 CAT
-40 °C to +80 °C (-40 °F to
+176 °F)
Polytron 5310 IR
-40 °C to +65 °C (-40 °F to
+149 °F)
Polytron 57x0 IR
-40 °C to +77 °C (-40 °F to
+170 °F)
-40 °C to +80 °C
+176 °F)
900 hPa to 1100 hPa
(26.5 in. Hg. to 32.4 in. Hg)
0 to 100% RH, non-condensing
-20 °C to +65 °C (-4 °F to +149 °F)
Max. 5 years
Polytron 5200 CAT
-40 to +70 °C (-40 °F to +158 °F)
Polytron 57x0 IR
-40 to +70 °C (-40 °F to +158 °F)
of the maximum specification.
for Ex approval and performance approval are identical.
WARNING
prevent damage.
|
en
Technical data
2)
(-40 °F to
2)
2)
(-40 °F to
2)
31