7. spin a third time;
At the end of the fourth calibration spin, the ma-
chine will automatically perform two subsequent
spins at different wheel rotational speeds that
are lower than the previous spins.
If the calibration has been successful, a permis-
sion acoustic signal goes off at the end of the
spin; otherwise, the E 2 message is temporarily
displayed.
Notes:
-
Once the procedure is finished, remove the
calibration weight.
-
Press the
calibration procedure at any time.
-
This calibration is valid for any kind of wheel.
Calibration of the ultrasonic
width sensor (if installed)
- select the ultrasonic width sensor calibration
icon
located in the configuration pro-
grammes;
- fix the calibration template in correspond-
ence of the threaded hole located in the shaft
assembly bell using the M8 screw (A, Fig.29)
supplied with the ultrasonic sensor;
- use the locking device with a wheel spacer (ma-
chine version with automatic locking system)
or a cone and the wheel fixing nut to bring the
template in contact with the shaft assembly
78
28
button to interrupt the
bell (fig.29);
- press the Kis knob or the ENTER button to
confirm the securing of the template;
- slowly turn the template towards the operator
to automatically enable the clamping brake
(fig.30);
- slowly lower the wheel guard (fig. 31), the ma-
chine will automatically calibrate the sensor.
If the calibration has been performed success-
fully, a consent message is displayed.
On the contrary, the display of the message A20
indicates that:
- the position of the calibration template during
the calibration phase is not correct. Therefore,
position the template correctly, checking that
the hole in the ultrasonic sensor support is
aligned with the calibration template (see figure