Function open / close
automatically locking C
If the control pedal C (L, Fig.11) or the WINUT
device fails to function, you can open/close the
locking device C in the following way:
- select the
- press the Kis knob or the ENTER key to open/
close the automatic locking device C.
This function can be inserted in the bar of the main
icons, as explained in Preferred Programme
Configuration.
CONFIGURATION
PROGRAMS
The Configuration programmes are those func-
tions that are intended for customising the
machine's operation and are normally executed
when the machine is installed.
The list of the configuration programmes can be
displayed as follows:
-
Select the utility and configuration pro-
grammes icon
Select the configuration programmes icon
-
.
Automatic Position Search
(RPA) Configuration
Enables/disables the automatic positioning of
the wheel at the end of the spin. After the list of
the setting programmes is displayed, proceed
as follows:
-
Select the Automatic position search con-
74
icon
.
figuration icon
The following icons are displayed:
RPA OFF; disables the automatic position search
procedure.
RPA ON; enables the automatic position search
procedure.
-
Press the
the Kis knob or
select the icon desired.
-
Press the
setting and exit.
The selection can also be seen in the working
screen status line.
Selection of adhesive weights
application position
To access this programme you must:
- select the Utility programmes icon,
- select the configuration programmes icon
- Three icons will appear on the display that
represent the possible positions, as shown
below:
H12: the balancing weight must always be applied
in the 12 o'clock position regardless of the type
of balancing programme selected or the type
of weight to be applied (adhesive or spring);
LASER: the balancing adhesive weight must be
applied in correspondence of the laser line
(in all balancing programmes) whereas the
clip weight must always be applied in the 12
o'clock position;
CLIP: the balancing adhesive weight must be ap-
plied using the weight holder in ALU1 and ALU2
programmes, whereas the spring weight must
always be applied in the 12 o'clock position.
- Use the Kis knob or the arrow buttons to se-
lect the desired position. The selected icon is
enabled if it is in the following configuration:
EM 9580 - Operator's manual
.
ENTER button to
Exit button to save the