- when the internal sensor is extracted. When
the sensor returns to the rest position, the
light turns off;
- during the entire measurement cycle with
all balancing programmes;
- during the Hidden Weight programme
when selecting the two planes behind the
spokes.
LEDOFF: deactivated
Press the Kis knob or the ENTER button to select
the desired mode. The selected icon is enabled
if it is in the following configuration:
- press
to confirm the selection made
and exit the function.
LASER activation/deactivation
It is possible to activate or deactivate the laser
when present on the machine.
After the list of the setting programmes is dis-
played:
- Select the LASER activation/deactivation icon
- Two icons will appear on the display that rep-
resent the possible LASER modes, as shown
below:
LASER OFF.
LASER ON. In this configuration, the laser
turns on in the following cases:
for the manual application of all adhesive
weights.
IMPORTANT:
If the operator selected the adhesive weight
application configuration using a CLIP, in the
Alu1 or Alu2 balancing programmes the laser will
not be activated as the weight will be applied
using the weight holder
In the Hidden Weight programme, the selection
of the two new positions behind the spokes is
done in the 6 o'clock position using the laser
line.
Press the Kis knob or the ENTER button to select
the desired mode
The selected icon is enabled if it is in the follow-
ing configuration:
EM 9580 - Operator's manual
- press
to confirm the selection made
and exit the function.
Sensitivity Calibration
Calibrate when detecting that the setting condi-
tion is out-of-tolerance or when the machine so
requires as the E 1 message is displayed.
Calibrate as follows:
1. Select the sensitivity calibration icon
. in the configuration program menu
.
2.
Fit a wheel of average or larger dimensions
preferably with only small unbalance on the
wheel balancer;
3. activate spinning;
4. At the end of the spin, fix the calibration
weight supplied with the machine on the
swinging unit bell as indicated in figure 27;
5. spin again;
6. At the end of the spin, change the position
of the calibration weight on the swinging unit
bell as indicated in figure 28;