H) Wheel support shaft
I)
Wheel guard
L) Control pedal C of the automatic wheel
clamping system
ELECTRICAL HOOK-UP
The wheel balancer is set up by the manufacturer
to operate with the power supply available in the
place of installation. The set-up data for each
machine are given on the machine data plate
and on a special label attached to the power
supply connection cable.
WARNING
Any operations for hooking up to the workshop
electrical board must be carried out only by
qualified technicians in compliance with the
regulations in force, under the responsibility
and at the charge of the customer.
The electrical hook-up must be performed
according to:
• Absorbed power specifications indicated on
the machine data plate.
• The distance between the machine and the
electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when
starting up) of the rated voltage specified on
the data plate.
- The user must:
• Connect the machine to its own electrical
connection fitted with a suitable 30-mA current
sensitive circuit breaker.
• Power line fuses in accordance with specifica-
tions in the main wiring diagram of this manual.
• Provide the workshop electric installation with
an efficient grounding circuit.
- Prevent unauthorised use of the machine,
always disconnect the power supply plug
when the machine is not used (switched off)
for extended periods of time.
- If the machine is connected directly to the power
supply by means of the main electrical board
and without the use of a plug, a key-operated
or padlockable switch must be installed to
restrict machine use exclusively to qualified
personnel.
WARNING
A good grounding connection is essential for
EM 9580 - Operator's manual
correct operation of the machine. NEVER connect
the machine ground wire to a gas pipe, water pipe,
telephone cable or any other unsuitable object.
COMPRESSED AIR
HOOK-UP
CAUTION
The compressed air hook-up may only be per-
formed if the pneumatic ring nut is supplied
(optional accessory supplied on request).
WARNING
All compressed air hook-ups must be carried
out by qualified personnel only.
- The hook-up to the workshop compressed air
system must ensure a minimum pressure of
8 bar.
- The union for connecting to the compressed air
system is of a universal type and therefore no
special or additional couplings are required.
A pressure-resistant hose with 6mm inner
diameter and 14mm outer diameter must be
fixed to the notched union using the hose clamp
provided with the machine.
SAFETY REGULATIONS
WARNING
Non-compliance with the instructions and
danger warnings can cause serious injuries to
the operator or other persons.
Do not operate the machine until you have read
and understood all the danger/warning notices
in this manual.
In order to operate the machine correctly, it is
necessary to be a qualified and authorised op-
erator, able to be trained and to know the safety
regulations. Operators are expressly forbidden
from using the machine under the influence of
alcohol or drugs capable of affecting physical
and mental capacity.
The following conditions are essential:
- Read and understand the information and
instructions described in this manual.
UK
51