Engine Control Module (ECM) Diagnostics
5.4
ECM Monitoring of Solenoids—Kubota Engine Only
The ECM monitors the wiring to, and condition of, the stop solenoid and the wiring
to, and condition of, the starter solenoid.
If the connector harness (a) to the stop solenoid is disconnected or the stop
solenoid is faulty, the following results occur.
■ The control panel indicators (b) will flash immediately after the transmitter is
turned on.
■ The red LEDs of the light ring will illuminate solid red.
■ The engine will not crank.
Reconnect the connector harness, check the wiring, or replace the stop solenoid to
enable the machine to start.
This procedure continues on the next page.
a
wc_gr012438
b
74
RT / RTx
wc_gr012437
wc_tx003818gb_FM10.fm