Indications on the status bar at the bottom of each page
Identifying
code
GO
SB
Disable
rpm
bar
FAULT
Presence of an error preventing operation of the electropump
The following may appear on the pages that show parameters: numerical values and units of measure of the current item, values of other
parameters linked to the setting of the current item, graphic bar, lists; see Figure 16.
8.4 Blocking parameter setting by Password
The device has a password-enabled protection system. If a password is set, the parameters of the device will be accessible and visible but it will not be
possible to change them. The password management system is in the "technical assistance" menu and is managed by means of the parameter PW.
8.5 Enabling and disabling the motor
In normal operating conditions, pressing and then releasing both the "+" and "-" keys causes the blocking/release of the motor (self-holding even after
switching off). If there is a fault alarm, the operation described above resets the alarm.
When the motor is disabled this status is shown by the blinking white LED. This command can be activated from any menu page except RF and PW.
9. MEANING OF THE INDIVIDUAL PARAMETERS
9.1 USER MENU
From the main menu, pressing the MODE key (or using the selection menu and pressing + o - ), gives access to the USER MENU.
In the menu the MODE key allows you to scroll through the various menu pages. The values shown are the following.
Status
RS: Rotation speed display
VP: Pressure display
VF: Flow display
PO: Absorbed power display
C1: Phase current display
Operating hours and number
of starts
PI: Power histogram
Multi-pump system
Status
Motor running
Symbol of pump turning
Motor stopped
Symbol of static pump
Device faulty
Symbol of static pump
If the device is configured as reserve the icon depicting the pump is dark in colour, the display remains similar to Table 9 with the exception that, if the
motor is stopped, it shows F instead of SB.
Output flow meter
Description
Motor stopped
Motor stopped
Motor status manually disabled
Motor revs per minute
Plant pressure
Displays the pump status.
Motor rotation speed in rpm.
Plant pressure measured in [bar] or [psi] depending on the measuring system used.
Displays the instantaneous flow in [litres/min] or [gal/min] depending on the set measuring system.
Power absorbed by the electropump in [kW].
A flashing round symbol may appear under the symbol of the measured power PO. This symbol indicates the pre-
alarm for exceeding the allowed maximum power
Motor phase current in [A].
A flashing round symbol may appear under the symbol of the phase current C1. This symbol indicates the pre-
alarm for exceeding the allowed maximum current. If it flashes at regular intervals it means that the motor overload
protection is about to trip and it will very probably go into protection status
Indicates on three lines the hours that the device has been powered up, the pump working hours and the number
of starts of the motor.
A histogram of the power delivered is displayed on 5 vertical bars. The histogram indicates how long the pump
has been on at a given power level. On the horizontal axis are the bars at the various power levels; on the vertical
axis, the time for which the pump has been on at the specific power level (% of the time with respect to the total).
Displays the system status when in the presence of a multi-pump installation. If communication is not present, an
icon depicting communication absent or interrupted is displayed. If there are several devices connected to one
another, an icon is shown for each of them. The icon has the symbol of a pump under which are characters
indicating the pump status. Depending on the operating status it will display as in Table 12.
System display
Icon
Status information under the icon
The page shows two flow meters. The first shows the total output flow delivered by the machine. The second shows a
partial count and can be reset by the user.
The partial count can be reset from this page, by holding down the " - " button for 2 sec.
ENGLISH
Table 11: Indications on the status bar
USER MENU
speed in three figures
SB
F
53
Table 12: View of the multi-pump
system