When the + key or the - key is pressed the selected value is modified and saved immediately in the permanent memory (EEprom). If
the machine is switched off, even accidentally, in this phase it does not cause the loss of the parameter that has just been set.
The SET key is only for leaving the current menu and is not necessary for saving the changes made. Only in particular cases described
in chapter 0 are some values updated by pressing "SET" or "MODE".
Warning leds
Power: White led. Lit with a fixed light when the machine is powered. Blinking when the machine is disabled (see par. 8.5).
Alarm: Red led. Lit with a fixed light when the machine is blocked by an error.
Communication: Blue led. Lit with a fixed light when communication wireless is used and is working correctly. t blinks with a slow frequency if
when configured to work in communication mode, communication is not available, is not detected, or there are problems. It blinks with a high
frequency during association with other wireless devices. Off if communication is not used.
Menus
L The complete structure of all the menus and of all the items of which they are composed is shown in Table 9.
Access to the menus
The various menus can be accessed from the main menu in two ways:
1 - Direct access with a combination of keys
8.1 Direct Access with a Combination of Keys
The desired menu can be accessed directly by pressing simultaneously the appropriate combination of keys for the required time (for example
MODE SET to enter the Setpoint menu) and the various items in the menu are scrolled with the MODE key.
Table 8 shows the menus that can be reached with the combinations of keys.
MENU NAME
User
Monitor
Setpoint
Manual
Installer
Technical assistance
Reset factory values
Reset
Reduced menu (visible)
Main Menu
User Menu
MAIN
STATUS
(Main Page)
Revs per minute
Pressure
Menu Selection
Display of flow
Power absorbed
by pump
Pump phase current
Hours switched on
Working hours
Number of starts
2 - Access by name with a drop-down menu
DIRECT ACCESS KEYS
Monitor Menu
mode
set-minus
CT
RS
Contrast
VP
BK
VF
Back lighting
PO
TK
Backlighting
switch-on time
C1
LA
Language
TE
Dissipator
temperature
ENGLISH
HOLD-DOWN TIME
On releasing the button
2 Sec
2 Sec
5 Sec
5 Sec
5 Sec
2 sec after switching on
appliance
2 Sec
Extended menu (direct access or password)
Setpoint Menu
Manual Menu
mode-set
set-minus-plus
SP
STATUS
Setpoint pressure
Speed setting
VP
Pressure
P1
VF
Auxiliary setpoint 1
Display of flow
PO
P2
Power absorbed
Auxiliary setpoint 2
by pump
C1
P3
Pump phase current
Auxiliary setpoint 3
RS
Revs per minute
P4
TE
Auxiliary setpoint 4
Dissipator
50
Table 8: Access to the menu
Installer Menu
mode-set-minus
RP
RI
Decrease
pressure
for restart
OD
Type of
plant
AD
Address
Configuration
MS
Measuring system
AS
Wireless Devices
Tech. Assist. Menu
mode-set-plus
TB
Block time for
water lack.
T1
Low pr delay
T2
Delay in switching off
GP
Proportional gain.
GI
Integral gain