Bitzer CSVH2 Mode D'emploi page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8 8 . . 2 2 R R e e p p l l a a c c e e o o i i l l f f i i l l t t e e r r
◦ Prepare a new oil filter.
Fig. 14: Drain the oil at the oil valve for maintenance (5)
Fig. 15: Oil filter flange (18)
• Place a flat pan under the oil valve for maintenance
(5) and the oil filter flange (18).
• Drain oil and dispose of it properly.
• Open the rectangular flange of the oil filter and re-
move it by pulling it forward.
The integrated oil filter is mounted on the rear side of
the flange.
• Unscrew the oil filter from the flange.
• Mount a new oil filter on the flange.
• Replace the O-ring on the hole at the top of the
flange.
• Insert the flange with the new oil filter and the new
flat gasket. Orient the hole with the O-ring upward.
Screws: M16x50
N N O O T T I I C C E E
!
!
Risk of damage to the compressor.
Tighten screws and nuts only to the prescribed
tightening torque and, if possible, crosswise in
at least 2 steps.
• Charge with new oil.
• Test tightness before commissioning.
SB-160-3
SB-160-3 RUS
5
5/8-18 UNF
18
4 x M16x50
8 8 . . 3 3 I I n n t t e e g g r r a a t t e e d d p p r r e e s s s s u u r r e e r r e e l l i i e e f f v v a a l l v v e e
The valve is maintenance-free. Its response pressure
difference is 21 bar.
However, after repeated venting, it may leak perman-
ently because of abnormal operating conditions. The
consequences are reduced performance and a higher
discharge gas temperature.
8 8 . . 4 4 I I n n t t e e g g r r a a t t e e d d c c h h e e c c k k v v a a l l v v e e
After being shut off, the compressor runs in reverse dir-
ection for a short time (approx. 5 s until pressure com-
pensation in the oil separator takes place). This period
will be longer if the check valve is damaged or clogged.
The valve needs to be replaced then.
R R e e p p l l a a c c i i n n g g t t h h e e i i n n t t e e g g r r a a t t e e d d c c h h e e c c k k v v a a l l v v e e
W W A A R R N N I I N N G G
The compressor is under pressure!
Serious injuries are possible.
Depressurize the compressor!
Wear safety goggles!
• Remove the discharge gas shut-off valve or the pipe
connection.
The check valve lies below it.
• Replace the check valve and both gaskets.
• Carefully mount the discharge gas shut-off valve or
the pipe connection.
When turning or mounting shut-off valves:
N N O O T T I I C C E E
!
!
Risk of damage to the compressor.
Tighten screws crosswise in at least 2 steps to
the prescribed tightening torque.
Test tightness before commissioning!
23