SYSTem:COMMunicate:LAN:WINS[{1|2}] "<address>"
SYSTem:COMMunicate:LAN:WINS[{1|2}]? [{CURRent|STATic}]
Assigns the static IP addresses of the Windows Internet Name System (WINS) servers. A primary and a
secondary server address may be assigned. If DHCP is available and enabled, DHCP will auto-assign
these server addresses. These auto-assigned server addresses take precedence over the static addresses
assigned with this command. Contact your LAN administrator for details.
If you change this setting, you must send
activate the new setting.
Parameter
nnn.nnn.nnn.nnn
Command: "
Query: {CURRent|STATic}. Default: CURRent.
Set a static primary WINS address:
SYST:COMM:LAN:WINS "198.105.232.4"
SYST:COMM:LAN:UPD
On the 34460A, this requires option 34460A-LAN or option 3446LANU.
l
The WINS addresses are stored in nonvolatile memory. They do not change when power has been off,
l
after a Factory Reset (*RST) or after an Instrument Preset (SYSTem:PRESet).
SYSTem:SECurity:IMMediate
l
CURRent: returns address currently being used by the instrument.
l
STATic: returns static address from non-volatile memory. This address is used if DHCP is disabled or
l
unavailable.
Keysight Truevolt Series Operating and Service Guide
Typical Return
"198.105.232.4"
". Default: "0.0.0.0".
sets this parameter to its default value.
SCPI Programming Reference
SYSTem:COMMunicate:LAN:UPDate
to
417