Assigning A Timer Switch Menu; T2 Sw - Multiplex COCKPIX SX Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Moving to the START1 menu:
to MENU,
to TIMER,
Start time for Timer 1 in minutes : seconds
The first number of the current start time flashes. Use
the 3-D digi-adjustor to set the "tens" of minutes. A brief
press
on the 3-D digi-adjustor takes you on to the
next digit.
Once you have set the "single second digits", a brief
press on the 3-D digi-adjustor concludes the process.
Important: the current time is stored.
The current time of Timer 1 is stored when you switch
the transmitter off. If you want the set time to start
again next time you switch on, you must first reset
Timer 1 in the INFO 2 or INFO 3 menu (long press
on the 3-D digi-adjustor).
If the assigned switch is at the ON position when you
switch the transmitter on again, Timer 1 immediately
resumes counting.
19.2. Timer 2
Timer 2 is ideal for recording the overall flight time. It
always starts at 00:00. The transmitter control selected
as the timer switch can start Timer 2, but it cannot stop
it again.
Timer 2 runs to a maximum of 99 minutes, 59 seconds.
Timer 2 can be started, for example, when the throttle
is advanced for the first time, when the tow-release is
operated, or when you operate the PH switch to switch
from the launch setting to normal flight.
19.2.1.
Assigning a timer switch

) T2 SW

TIMER
Menu: (
Example 1: starting Timer 2 using the THROTTLE
In this case the switch is assigned using the method
described in section
19.1.1.
Example 2: starting Timer 2 using the PH switch
Requirements:
The model must be programmed with flight phases.
Flight phase 1 is the "launch setting", and flight phase 2
is "normal flight".
The following example shows how to start Timer 2 (with
the stated requirements fulfilled), when you switch for
the first time from the "launch setting" to "normal flight".
(SETUP appears),
(START1 appears),
Operating Instructions
Moving to the T2 SW menu:
to MENU,
to TIMER,
to T2 SW
No switch
Move the PH switch quickly to and fro until code num-
ber 4 appears. The hyphen following the colon indi-
cates the switch position which triggers the timer.
Switch 4
Now move the PH switch to the position which is re-
quired to trigger the timer (in our illustration Phase 2).
A brief press
on the 3-D digi-adjustor concludes the
process. The flashing ceases, and the setting is stored.
19.2.2.
Stopping Timer 2, or resetting it to 00:00
Timer 2 can only be stopped or reset if it is visible in
the bottom line of the screen. There are two methods of
doing this:
In the INFO 3 display:
Pressing the 3-D digi-adjustor at this display affects
both timers.
INFO 3 display: both timers
In the INFO 4 display:
Pressing the 3-D digi-adjustor at this display only af-
fects Timer 2.
INFO 4 display: Timer 2 only
Stop timer:
Setting timer to 00:00:
Page 77
(SETUP appears),
(START1 appears),
Switch 4
Phase 3
Phase 2
Phase 1
Marker Switch position
brief press on 3-D digi-adjustor
long press on 3D digi-adjustor

Publicité