Télécharger Imprimer la page

Wilo -EMU TR 50-2 Serie Notice De Montage Et De Mise En Service page 319

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 426
9.4.1
Maintenance intervals for normal
conditions
9.4.2
Maintenance intervals for harsh
conditions
9.5
Maintenance measures
9.5.1
Recommended maintenance
measures
9.5.2
Visual inspection of the connec-
tion cable
Installation and operating instructions Wilo-EMU TR/TRE 50-2 ... 120-1
Maintenance and repair
8000 operating hours or after 2 years at most
▪ Visual inspection of the connection cable
▪ Visual inspection of cable brackets and cable tensioning
▪ Visual inspection for wear of the mixer
▪ Function test of monitoring devices
▪ Visual inspection of accessories
▪ Oil change
15000 operating hours or after 10 years at the latest
▪ General overhaul
Under harsh operating conditions, the specified maintenance intervals must be
shortened as required. Harsh operating conditions include:
▪ Fluids with long-fibre components
▪ Strongly corrosive or abrasive fluids
▪ Highly gaseous fluids
▪ Operation at an unfavourable duty point
▪ Unfavourable flow conditions (e.g. due to fixtures or aeration)
When using the mixer under harsh conditions, it is recommended that a maintenance
contract be entered into. Contact customer service.
WARNING
The propeller blade has sharp edges!
Sharp edges can form on the propeller blades. There is a risk of limbs being severed.
Wear safety gloves to protect against cuts.
WARNING
Hand, foot or eye injuries due to the absence of protective equipment!
Danger of (serious) injuries during work. Wear the following protective equipment:
• Safety gloves for protection against cuts
• Safety shoes
• Closed safety goggles
The following preconditions must be fulfilled prior to the start of maintenance meas-
ures:
▪ Motor must have cooled down to the ambient temperature.
▪ Mixer must be thoroughly cleaned and disinfected (if required).
Regular inspection of current consumption and the operating voltage in all three phases
is recommended for smooth operation. In normal operation, these values remain con-
stant. Slight fluctuations depend on the characteristics of the fluid.
Current consumption can provide an early indication of damage to or malfunctions in
the mixer, which can then be rectified. Larger voltage fluctuations strain the motor
winding and can cause breakdown. Regular inspections can therefore largely prevent
major secondary damage and reduce the risk of total breakdown. In this regard, it is re-
commended to use remote monitoring for regular inspections.
Check connection cable for:
▪ Bubbles
▪ Cracks
▪ Scratches
▪ Abrasion
▪ Pinch points
▪ Changes caused by chemical corrosion
If damage to the connection cable is identified, decommission the mixer immediately!
Have the connection cable replaced by Wilo customer service. Only start the mixer up
again once the damage has been properly remedied!
en
319

Publicité

loading