6.4.2
Wall fixation
Fig. 4: Wall fixation
6.4.3
Ground installation
Fig. 5: Ground installation
Installation and operating instructions Wilo-EMU TR/TRE 50-2 ... 120-1
Installation and electrical connection
10.Restore corrosion protection: Seal screw plug, e.g. with Sikaflex.
In the case of wall fixation, the mixer is mounted either on a mounting bracket or dir-
ectly on the basin wall. The mixer can be horizontally pivoted with the mounting
bracket. Lay the connection cable against the basin wall and lead it upwards.
Operating space/installation location is prepared for the installation. Defined clear-
ances to fixtures and basin walls are kept in accordance with the consulting docu-
ments.
Mixer is not connected to the mains.
For installation at heights over 1 m, use scaffolding with a safety harness.
1. Position the mixer at the basin wall using hoisting gear and mark the mounting
holes.
2. Set the mixer down outside of the working area.
3. Drill fixation holes and insert anchor bolts. NOTICE! Follow the manufacturer's in-
stallation instructions!
4. Once the anchor bolts have hardened in place, use the hoisting gear to place the
mixer on the anchor bolts and fix in place with fixation material.
5. Fix the mixer firmly against the basin wall. NOTICE! Follow the manufacturer's in-
stallation instructions!
6. Lay the connection cable against the basin wall so that it is slightly taut. CAU-
TION! If the connection cable leads over the edge of the basin, beware of po-
tential abrasion. Sharp edges may damage the connection cable. Bevel the basin
edge if necessary!
7. Apply corrosion protection (e.g. Sikaflex): Fill the slotted holes on the motor flange
up to the washer.
▶ Mixer is installed. Make the electrical connection.
In the case of ground installation, the mixer is fixed directly to the floor of the basin us-
ing a mounting bracket. CAUTION! If the mixer is ordered for ground installation, the
mounting bracket comes pre-assembled. If the mixer is delivered without a mount-
ing bracket, order the appropriate mounting bracket from customer service! Lay the
connection cable along the basin floor and upwards up the basin wall.
Operating space/installation location is prepared for the installation. Defined clear-
ances to fixtures and basin walls are kept in accordance with the consulting docu-
ments.
Mixer is not connected to the mains.
Mounting bracket mounted on the mixer.
1. Use hoisting gear to position the mixer on the basin floor and mark 2 fixation holes.
2. Set the mixer down outside of the working area.
3. Drill fixation holes and insert anchor bolts. NOTICE! Follow the manufacturer's in-
stallation instructions!
4. Once the anchor bolts have hardened in place, use the hoisting gear to place the
mixer on the anchor bolts and fix in place with fixation material.
5. Mount the mixer firmly against the basin floor. NOTICE! Follow the manufac-
turer's installation instructions!
6. Lay the connection cable against the basin floor and the basin wall so that it is
slightly taut. CAUTION! If the connection cable leads over the edge of the basin,
beware of potential abrasion. Sharp edges may damage the connection cable.
Bevel the basin edge if necessary!
7. Apply corrosion protection (e.g. Sikaflex):
- Sealing joint between mounting bracket and structure.
- Fill holes in the baseplate of the mounting bracket.
- Fill scratches in the mounting bracket.
▶ Mixer is installed. Make the electrical connection.