d) Binding function
In order for the transmitter and the receiver to commu-
nicate with each other, they must be bound using the
same digital coding. When delivered, the transmitter
and receiver are already coordinated and can be used
2
immediately. The renewal of the Binding function is, pri-
1
marily, only necessary after switching a transmitter or
receiver or when eliminating faults.
3
The transmitter and receiver are not bound if the LED
in the receiver only fl ashes in spite of the transmitter
being on.
If the transmitter has lost the binding with the receiver
due to an interference, or if you want to bind a new
receiver to the transmitter, proceed as declared below.
Remove all servo plugs, as well as any present external
power supply, from the receiver. Connect the binding
Figure 6
plug (short-circuit plug) to the receiver on B/VCC. Con-
nect a receiver battery to a free channel (e.g. CH1). Switch on the receiver power supply. The receiver LED fl ashes
very fast. Switch on the transmitter now. Select the menu „RX-Setup". Select the function „Bind with a receiver" in
this menu. The transmitter asks in the English language if you really want to bind to a receiver. Confi rm with „yes".
Binding was successful if the receiver LED is permanently lit. Now switch off the receiver power supply and remove
the binding plug. Only now can all servos and any external power supply be connected again and the receiver be
used. Check the correct function of the connected servos/speed controllers before operating the model and perform
a range check.
59