Calibrate Control Stick - Reely HCP80 3D RtF Notice D'emploi

Hélicoptère 3d
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

15. Calibrate Control Stick

For best control of the model helicopter, the path of the control sticks must be precisely recorded electronically. The
paths are set ex works but can be calibrated anew at any time. For this, the „ENGINEER" mode must be called.
• Push and hold the buttons „SELECT" and „INC (+)" and
switch on the transmitter with the buttons pushed.
• When the „ENGINEER" mode is displayed, release the but-
tons again.
Calibration starts with the right control stick „RIGHT STICK",
which must be deflected horizontally to the left „Hori axis
LEFT" to the stop. According to the stick path, the electroni-
cally recorded movement value changes (lower right in the
display).
• Deflect the right control stick to the left to the stop and hold
it in this position. Now push the button „SELECT" to save
the value.
• The display shows „SET OK".
• Push the button „DOWN" to then save the horizontal middle
position „Hori axis CENTER" of the right control stick.
• Let the right control stick spring back to the middle position
and push the button „SELECT" to save the value.
• The display shows „SET OK".
• Push the button „DOWN" to save the right horizontal deflec-
tion „Hori axis RIGHT" of the right control stick.
• Deflect the right control stick to the right to the stop and hold
it in this position. Now push the button „SELECT" to save
the value.
• The display shows „SET OK".
Figure 49
117

Publicité

Table des Matières
loading

Table des Matières