Lisäkäyttöohjeet - reiälliset trakeostomiaputket (FEN, CFN)
VAROITUKSIA:
ON KIINNITETTÄVÄ ERITYISTÄ HUOMIOTA REI'ITYKSEN AVOIMUUDEN
YLLÄPITOON, VARSINKIN SELLAISTEN POTILAIDEN KOHDALLA, JOILLA ESIINTYY
PAKSUA, SITKEÄÄ ERITETTÄ, JOKA SAATTAA TUKKIA REIÄT. ASIANKUULUVAA
ILMANKOSTUTTAJAA TULEE KÄYTTÄÄ TARVITTAESSA EDISTÄMÄÄN STOOMA-
AUKON PYSYMISTÄ AVOIMENA. VAROVAISUUTTA TÄYTYY NOUDATTAA
FEN- JA CFN TRAKEOSTOMIAPUTKIEN VALINNASSA JA SIJOITTAMISESSA,
JOTTA MINIMOITAISIIN KOMPLIKAATIOITA, JOITA SAATTAA ESIINTYÄ
RAKEISEN KUDOKSEN VUOKSI. REI'ITYKSEN TUKKEUMAT SAATTAVAT ESTÄÄ
REIÄTTÖMÄN, VALKOISELLA 15 mm LIITTIMELLÄ VARUSTETUN SISÄKANYYLIN
(TARPEELLINEN MEKAANISESSA VENTILOINNISSA) PAIKALLEEN ASETTAMISEN
TAI NE SAATTAVAT VAIKEUTTAA ILMAN PÄÄSYÄ YLEMPIIN HENGITYSTEIHIN.
TÄSSÄ TAPAUKSESSA ON FEN- TAI CFN-TRAKEOSTOMIAPUTKI MAHDOLLISESTI
VAIHDETTAVA JOHONKIN MUUN TYYPPISEEN PUTKEEN.
JOS KÄYTETÄÄN REIÄLLISTÄ PUTKEA (FEN tai CFN), ON IMUN AIKANA
KÄYTETTÄVÄ VALKOISELLA 15 mm LIITTIMELLÄ VARUSTETTUA SISÄKANYYLIA
ESTÄMÄÄN IMUKATETRIA TYÖNTYMÄSTÄ TRAKEOSTOMIAPUTKEN REIKIEN
LÄVITSE. IMUN SUORITTAMINEN ILMAN ETTÄ REIÄTÖN SISÄKANYYLI ON
ASETETTU PAIKALLEEEN, SAATTAA AIHEUTTAA VAURIOITA HENKITORVEN
SEINÄMIIN JA SE VOI AIHEUTTAA IMUKATETRIN JUUTTUMISEN REI'ITYKSEEN.
JOS SISÄKANYYLIA PAIKALLEEN ASETETTAESSA REI'ITYKSEN KOHDALLA
TUNTUU VASTUSTUSTA, SISÄKANYYLIA EI SAA TYÖNTÄÄ VÄKISIN KANYYLIN
LÄVITSE. ASIASTA ON HETI ILMOITETTAVA HOITOHENKILÖKUNNALLE.
REIÄLLISIÄ TRAKEOSTOMIAPUTKIA EI KOSKAAN TULE KÄYTTÄÄ MEKAANISEEN
VENTILAATIOON ELLEI VALKOISELLA 15 mm LIITTIMELLÄ VARUSTETTU
REIÄTÖN SISÄKANYYLI OLE ESTÄMÄSSÄ VUOTOA REIKIEN LÄVITSE.
103