Maintenance
Remedial De-scaling & Sanitizing
Procedure
This procedure de-scales/sanitizes all
components in the water flow path, and is
used to de-scale/sanitize the ice machine
between the bi-yearly detailed de-scaling
and sanitizing procedure.
Ice machine de-scaler is used to remove
lime scale and mineral deposits. Ice
machine sanitizer disinfects and removes
algae and slime.
Step 1
Remove front panel and top
cover. This will allow easiest access for
adding De-scaler and Sanitizer.
Step 2
Ice must not be on the evaporator
during the de-scalesanitize cycle. Use one
of these methods:
• Set the toggle switch to the OFF position
after ice falls from the evaporator at the
end of a Harvest cycle.
• Set the switch to the OFF position and
allow the ice to melt off the evaporator.

Notice
Never use anything to force ice from the
evaporator. Damage may result.
38
Step 3
Remove all ice from the bin.
Step 4
Place the toggle switch in the
CLEAN position. The water will flow
through the water dump valve and down
the drain. Wait until the water trough refills
and water flows over the evaporator, then
add the proper amount of ice machine
de-scaler or sanitizer.
Amount of Solution
De-scaler (#9405463): 16 oz (475 ml)
Sanitizer (#9405453): 25 oz (740 ml)
Step 5
Wait until the CLEAN cycle is
complete (approximately 80 minutes).
Step 6
Move the toggle switch to the
ICE position and replace the front panel.
The ice machine will automatically start ice
making after the cycle is complete.
Part Number 000017556 Rev 00 9/22