D. Remove ice thickness probes
• Compress the hinge pin on the top of
each ice thickness probe.
• Pivot the ice thickness probe to
disengage one pin then the other. The
ice thickness probe can be cleaned at
this point without complete removal. If
complete removal is desired, disconnect
the ice thickness control wiring from the
control board.
E. Remove the Water Pump Assembly
• Disconnect the vinyl distribution tube
from both water pumps.
• Disconnect the water pump and water
level probe electrical connections.
• After the wires are disconnected remove
the two thumbscrews and lift the water
pump assembly out of the ice machine.
• Remove the thumbscrews securing the
water pumps (2 each pump) and remove
water pumps. Do not immerse the water
pump motor in cleaner or sanitizer
solutions. Remove the water level probe
from the assembly housing.
A
C
Part Number 000017556 Rev 00 9/22
B
E
D
F. Remove the water trough
• Pull forward on the water trough to
remove
G. Remove distribution tubes
NOTE: Each evaporator has a distribution
that must be removed - total of four
distribution tubes.
• Distribution tube thumbscrews are
retained to prevent loss. Loosen
thumbscrews but do not pull
thumbscrews out of distribution tube
• Loosen the two outer screws and pull
forward on the distribution tube to
release from slip joint.
• Disassemble distribution tube
by loosening the two (2) middle
thumbscrews and dividing the
distribution tube into two pieces.
H. Remove ice dampers
NOTE: Each evaporator has an ice damper
that must be removed - total of four ice
dampers.
• Grasp ice damper and apply pressure
toward the back mounting bracket.
• Apply pressure to the front mounting
bracket with thumb.
• Pull ice damper downward when the
front ice damper pin disengages.
G