Maintenance
Step 7
Wait until the water trough refills
and water flows over each evaporator
(approximately 3 minutes). Add the
proper amount of Manitowoc Ice Machine
Sanitizer to the water trough by pouring
between the water curtain and evaporator.
Amount of Sanitizer
(#9405453)
25 oz (740 ml)
Step 8
Move the toggle switch to the
ICE position and replace the front panel.
The ice machine will automatically start ice
making after the sanitize cycle is complete
(approximately 80 minutes)
36
Parts Removal for Detailed De-scaling
& Sanitizing
Notice
Electrical connector must never be
exposed to any liquids.
A. Remove front evaporator shield
• Remove four quarter turn connectors.
• Remove front evaporator shield.
B. Remove left and right evaporator top
covers
• Remove two thumbscrews from the
front of each evaporator top cover.
• Lift front of cover, pull forward to
remove.
C. Remove splash shields
NOTE: Each evaporator has a splash shield
that must be removed - total of four splash
shields.
• Grasp the top center of splash shields.
• Lift up and then out.
Part Number 000017556 Rev 00 9/22