Section 3
Ice Thickness Check
After a harvest cycle, inspect the ice cubes
in the ice storage bin. The ice thickness
probe is factory‑set to maintain the ice
bridge thickness at 1/8" (3 mm).
NOTE: Make sure the water curtain is
in place when performing this check. It
prevents water from splashing out of the
water trough.
1.
Inspect the bridge connecting the
cubes. It must be approximately
1/8" (3 mm) thick.
2.
If adjustment is necessary, turn the
ice thickness probe adjustment
screw clockwise to increase bridge
thickness, counterclockwise to
decrease bridge thickness. Set at 1/4"
(6 mm) gap between ice machine and
evaporator as starting point, then
adjust to achieve a 1/8" (3 mm) bridge
thickness.
NOTE: Turning the adjustment one‑third of
a turn will change the ice thickness about
1/16" (1.5 mm).
Part Number 000017556 Rev 00 9/22
ADJUSTING SCREW
1/8" (3 MM) ICE
BRIDGE THICKNESS
PLACE 9/32" (7 MM)
DRILL BIT BETWEEN
PROBE AND
EVAPORATOR TO SET
INITIAL GAP
NOTE: Verify the ice thickness probe wire
doesn't restrict probe movement.