Operation
Safety Limits
Safety Limits are stored and indicated by
the control board after three cycles. The
number of cycles required to stop the ice
machine varies for each Safety Limit.
• Safety Limit 1 ‑ If the freeze time
reaches 60 minutes, the control board
automatically initiates a harvest cycle.
If 6 consecutive 60 minute freeze cycles
occur, the ice machine stops.
• Safety Limit 2 ‑ If the harvest time
reaches 7 minutes, the control board
automatically returns the ice machine
to the freeze cycle. If 500 consecutive
7 minute harvest cycles occur, the ice
machine stops.
• Safety Limit 3 If the low refrigerant
pressure control opens, the ice machine
shuts off and starts a 5 minute delay
period. If 3 consecutive low pressure
events occur the ice machine stops and
flashes the harvest light.
Use the following procedures to determine
if the control board contains a safety limit
indication.
• Move the toggle switch to OFF.
• Move the toggle switch back to ICE.
Watch the safety limit lights/harvest light
on the control board. If a safety limit has
been recorded, the corresponding light
will blink once, twice or three times to
indicate which safety limit stopped the
ice machine.
30
Minimum/Maximum Slab Weight
Adjust ice thickness to meet chart
specifications.
Minimum Ice
Evaporator
Weight Per
Single
6.38 lbs
Evaporator
(2.9 kg)
Dual
24.4 lbs
Evaporator
(11.07 kg)
Notice

Routine adjustments and maintenance
procedures are not covered by the
warranty.

Notice
Scroll refrigeration compressors must be
operated for a minimum break in period
of 24 hours before full ice production will
be reached.
Part Number 000017556 Rev 00 9/22
Section 3
Maximum Ice
Weight Per
Cycle
Cycle
7.13 lbs
(3.2 kg)
27.5 lbs
(12.5 kg)