Section 2
Maximum and Minimum Circuit Amperage
Due to continuous product improvements, this information is for reference only. Please
refer to the ice machine data plate to verify electrical data. Model/Serial data plate
information overrides information listed on this page.
Unit
ST3000
Head Section
SF3000C
QuietQube
Head Section
CVDF3000
Condensing
Unit
* Verify the direction of the rotation is correct on the 3ph scroll compressor. The ice machine will have
high suction pressure, low discharge pressure and will be noticeably loud. Reverse two incoming power
leads to reverse rotation.
Minimum Power Cord Specifications
Maximum
Minimum
Breaker
Wire Size
Size
15 amp
14 gauge
30 amp
10 gauge
If a power cord is used, the wire size to the
receptacle is dependent upon location,
materials used, length of run, etc., so
it must be determined by a qualified
electrician. Local, state or national
requirements will supersede our minimum
requirements.
Part Number 000017556 Rev 00 9/22
Voltage/Phase/
Cycle
208‑230/3/60
115/1/60
208‑230/3/60
Maximum
Length of Power
Cord
6 feet (1.83 m)
6 feet (1.83 m)
Maximum
Minimum
Fuse/Circuit
Circuit Amps
Breaker
30 amp
15 amp
35 amp
Minimum Wire
Size Required by
Manitowoc
30.0
#14 Solid Copper
2.0
Conductor
#8 Solid Copper
30.0
Conductor
Installation
N/A
17