CODE
CODE
SECONDAIRE
PRINCIPAL
23
13
23
14
23
15
24
12
24
23
25
0
25
11
25
22
25
33
25
44
25
55
25
66
25
77
32
0
32
33
32
55
32
77
33
12
33
23
34
12
34
13
DESCRIPTION
Primary Shift Selector
Mode Function Fault
Secondary Shift Selector
or RSI Link Fault
Secondary Shift Selector
Mode Function Fault
Sump oil temperature, cold
Sump oil temperature, hot
Output speed reasonableness
test, detected at 0 speed, (L)
Output speed reasonableness
test, detected at 0 speed, (1st)
Output speed reasonableness
test, detected at 0 speed 2nd
Output speed reasonableness
test, detected at 0 speed, 3rd
Output speed reasonableness
test, detected at 0 speed, 4th
Output speed reasonableness
test, detected at 0 speed, 5th
Output speed reasonableness
test, detected at 0 speed, 6th
Output speed reasonableness
test, detected at 0 speed, R
C3 pressure switch open,
L range
C3 pressure switch open,
3rd range
C3 pressure switch open,
5th range
C3 pressure switch open,
R range
Sump oil temperature
sensor, low
Sump oil temperature
sensor, high
EEPROM, factory cal.
compatibility number wrong
EEPROM, factory
calibration block checksum
TÉMOIN
« CHECK
TRANS »
Non
Non
Non
Oui
Non
Oui
Oui
Oui
Oui
Oui
Oui
Oui
Oui
Oui
Oui
Oui
Oui
Non
Non
Oui
Oui
8-17
INFORMATION TECHNIQUE
RÉPONSE
Mode change not permitted
Hold in last valid direction
Mode change not permitted
DNS
No upshifts above a
calibration range
DNS, Lock in current
range (L)
DNS, Lock in current
range (1 st)
DNS, Lock in current
range (2nd)
DNS, Lock in current
range (3rd)
DNS, Lock in current
range (4th)
DNS, Lock in current
range (5th)
DNS, Lock in current
range (6th)
DNS, Lock in current
range (R)
DNS, Lock in current
range (L)
DNS, Lock in current
range (3rd)
DNS, Lock in current
range (5th)
DNS, Lock in current
range (R)
Use default value of
200ø F (93ø C)
Use default value of
200ø F (93ø C)
DNS, SOL OFF
(Hydraulic default)
DNS, SOL OFF
(Hydraulic default)