Select "Yes" (ok) in the indicated display text and set the following
parameters:
•
U-value of the thermopane glazing of your conservatory (to be
requested from your conservatory specialist dealer)
•
Speed level that is to be used for recirculation.
WFL wireless supply air unit:
•
The display shows:
If you confirm twice with ok, the selected
ventilator may be manually opened with +
and manually closed with -.
•
Select "No" (menu) in order to adjust the automatic settings for this
ventilator. The following parameters are requested:
•
Humidity above which the supply air system is to be opened
•
Indoor temperature above which the supply air system is to be
opened
•
Winter set-up (outdoor temperature below which the supply air flap
remains closed)
•
Summer set-up (supply air system closed if outdoor temperature
higher than indoor temperature)
•
Time period for forced ventilation
Daikin wireless air-conditioning unit:
•
The display shows:
If you confirm twice with ok, the selected
air-conditioning unit may be manually
switched off with + and – or switched to automatic operation.
•
Select "No" (menu) in order to adjust the automatic settings for this air-
conditioning unit. The following parameters are requested:
•
Indoor temperature above which cooling is to start
•
Cooling level ("automatic mode" or "level 1" to "level 5")
•
Indoor temperature above which heating is to start
•
Heating level ("automatic mode" or "level 1" to "level 5")
•
Whether the unit is to ventilate in its non-operating state and if yes,
at what level (1...5)
•
Period of time during which ventilation shall be deactivated after the
unit was in operation (20 to 480 minutes).
As soon as an air-conditioning unit starts, the ventilators are
Do you want to
operate WFL no.x
manually?
Yes = ok No = menu
Do you want to
operate Daikin x
manually?
Yes = ok No = menu
93