Automatic functions for awnings:
Indoor awnings, without rain and wind alarm
Outdoor awnings, with rain and wind alarm
Extending the awnings depending on sun intensity and altitude
Not extending the awnings below a selectable outside temperature
Blocking the awnings until reaching a selectable indoor temperature
Retracting the awnings if a selectable wind speed is exceeded
The awnings are automatically retracted after falling below the set values, or in
case of rain/wind alarm.
Automatic functions for blinds:
Extending the blinds depending on sun intensity and altitude, with
adjustable automatic positioning and reversing system
Fully extending the blinds in a selectable time period (f. ex. each night from
20:00 until 8:00 as screen)
Fully extending the blinds at night (screen)
Retracting the blinds if a selectable wind speed is exceeded
Not extending the blinds below a selectable outdoor temperature
Blocking the blinds until reaching a selectable indoor temperature
Automatic functions for heating (please note: the multifunctional relay can only
be configured as heating or cooling system):
Switch on heating if a selectable indoor temperature is fallen below
Night reduction feature of the heating over an adjustable period of time,
and up to a selectable indoor temperature
Automatic functions for cooling (please note: the multifunctional relay can only
be configured as heating or cooling system):
Switch on cooling if a selectable indoor temperature is exceeded
Automatic functions for ventilation:
Ventilation if a selectable indoor temperature is exceeded
Ventilation if a selectable humidity is exceeded in the conservatory
Minimum and maximum speed of the ventilator may be adjusted
Daily forced ventilation over an adjustable period of time