After pressing the menu key, use the + or – keys to select the menu "Set
ventilation/air-conditioning or operate manually". Confirm with ok.
By using + and – you may now select the individual connected ventilator
controls, wireless ventilators (WL610, WL305, WFL) and Daikin air-
conditioning units.
Set ventilator
WGBL x or operate
manually?
Keys: menu + ok -
A maximum of 8 ventilators/air-conditioning units may be connected.
Confirm the desired ventilator/air-conditioning unit with ok.
Ventilator at WGBL ventilator module:
The display shows:
If you confirm twice with ok, the selected
ventilator may be manually controlled with
+ and -.
Choose "No" (menu) in order to adjust the automatic settings for this
ventilator. Depending on the selected basic setting for the ventilator
("supply air/extracted air mode" or "fresh air/heating"), parameters for
automatic ventilation will be requested:
Indoor temperature at which ventilation starts
Humidity at which ventilation starts
Minimum and maximum level of ventilation
Winter set-up (outdoor temperature below which the ventilation flaps
remain closed)
Time period for forced ventilation
Speed level for forced ventilation
Additionally for fresh air/heating:
Time period for night reduction of the heating system
Indoor temperature to which reduction is to take place
Set WL305/610 no. x
or operate manually?
Keys: menu + ok -
Do you want to
operate ventilator
WGBL x manually?
Yes = ok No = menu