shading, the allocation of the keys on the key pad of you control will be
changed so that the direction of the arrow corresponds with the direction of
travel of the awning. Confirm you configuration with ok. If you have
selected "No" (cover will roll out from the bottom to the top), the message
"Manual key assignment for channel x changed!" will appear, which you
have to confirm.
•
You may now check and correct the rotational direction of the motor, if
required, as described in "Basic adjustment of windows" (p. 110).
•
You may deactivate the daily reset in the automatic mode for this channel.
The awning will then remain in manual mode, if it was once operated
manually (rain and wind alarm are also active in manual mode). The default
setting is "No" (automatic reset activated).
You will automatically get to the adjustment of the next channel, or of the other
connected components.
Basic adjustment of blinds
Select "blind" in the basic setting of the channel, and confirm with ok.
•
In the basic adjustment of a blind, the rotational direction of the motor may
be checked and corrected, if necessary, as described in the "Basic
adjustment of windows" (p. 111).
•
You may deactivate the daily reset in the automatic mode for this channel.
The awning will then remain in manual mode, if it was once operated
manually (rain and wind alarm are also active in manual mode). The default
setting is "No" (automatic reset activated).
You will automatically get to the adjustment of the next channel, or of the other
connected components.
Basic adjustment of the ventilation units at WGBLs
This item will only be displayed if you have connected WGBLs (ventilation
modules)!
•
After allocation of the channels (see above),
the display will show:
With the + and – keys, you may now select
whether the WGBL controls a supply and extracted air system (with supply
112
Setting WGBL:
WGBL x operation mode
supply/extracted air
Keys: + ok -