Basic adjustment of windows
Select "window" in the basic setting of the channel, and confirm with ok.
•
You may select whether this window is to
be closed in case of rain, or not. Adjust the
setting with + or – and confirm with ok.
•
You may now select one of 3 operating modes for this window.
Normal open/close means that the window will always fully open or close
if corresponding commands are given.
In the sliding roof mode the runtime of the window motor will be preset
with a time that may be adjusted by you. With sliding roofs it is not
necessary in normal ventilation mode to utilise the entire travel.
If the sliding roof is to be fully opened, this may be done manually.
If the operating mode is move in stages, the control will check the room
temperature every 3 minutes. If the temperature is close to the set
temperature, the window will not move. If the temperature is next to the set
temperature, the window will travel one step, the length of which you may
adjust.
Confirm you selection with ok.
•
If you have selected sliding roof operation or single-step operation, the
display will show:
For sliding roof
enter runtime in
seconds 5 secs
Keys: + ok -
You may set the runtime with sliding roof operation, or the length of steps
with single-step operation.
Not all motors are suitable for moving in stages or for sliding
roof operation. Please ask your motor supplier.
•
After confirmation with ok, the rotational
direction will be checked.
110
Window x to close
automatically in
case of rain? No
Keys: + ok -
For moving in stages
enter increment in
or
seconds 5 secs
Keys: + ok -
Check direction of
rotation for motor
of window x?
Keys: + ok -
No