Routine Maintenance; Moving The Machine - SICE S 45 Manuel D'instructions

Demonte-pneus automatique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

WARNING!
Before making any inspection, adjustment or repair be certain power source is disconnected:
1) disconnect the machine from the mains electric supply.
2) disconnect the machine from the compressed air circuit by detaching the compressed air line from the quick
couple.
Perform the following routine maintenance operations:
1) From time to time (about every 15 days) check the oil level in the lubricator, which should
be between the "MIN" and "MAX" indicators on the jar (1, Fig. V).
Top up as needed as follows:
- Unscrew the jar (1, fig. V)
- Top up with ISO VG 32 viscosity ISO HG class oil for compressed air circuit (such as ESSO
Febis K32; Mobil Vacouline Oil 1405; KLUBER Airpress 32).
2) Every 2 or 3 days check if after every 2 or 3 pedal movements (3 or 5, Fig. P) a drop of
oil falls into the lubricator glass cup.
If it does not, adjust the lubricator regulating screw using a screwdriver (see Fig. V).
3) Clean the machine daily to remove any dirt or tyre debris from the wheel clamp jaw slides.
Lubricate these slides using ISO VG 68 viscosity ISO HG class grease (such as, for example
ESSO Febis K68; Mobil Vactra 2; Shell Tonna Oil 68).
4) To ensure correct operation of the inflation device pressure limiter (Refer to the section
on "SAFETY DEVICES", p. 27 of this manual, it is essential to carry out the following routine
checks:
- Check the water level in the water trap to the air supply (2, Fig. V), which must NEVER exceed the "MAX DRAIN" level indicator on the
water trap itself.
When necessary, drain the water by turning the locking ring (3, Fig. V) clockwise.
- Every 30-40 days disconnect the machine from the compressed air circuit and dismantle the glass (2, Fig. V) to remove any solids collected
inside it.

12. MOVING THE MACHINE

Follow the procedures outlined below when moving the machine:
1) Close the turntable grippers all the way towards the centre.
2) Turn the table so that the its straight sides are lined up the projected line of the side
panels (See Fig. Z/1).
3) Disconnect all power sources.
4) Clamp the pedal (7, Fig. P) with a wedge underneath it.
5) Remove the horizontal arm casing by unscrewing the fixing nuts (1, Fig. Z/2).
6) Move the horizontal arm (11, Fig. P) all the way back.
7) Sling the machine with lifting straps at least 60 mm wide.
8) Pass the first strap behind the horizontal arm as shown in Fig. Z/3.
S 45

11. ROUTINE MAINTENANCE

58
ENGLISH • Instructions manual
2
3
1
1
V
Z/1
Z/2

Publicité

Table des Matières
loading